Who can use this?
Platform: Windows
From version: Krisp 2.0.0
Info
This article is intended for IT Admins. If you’re a user facing any issues while installing Krisp, check other installation-related articles in the Troubleshooting section.
Below is the list of the most common error codes that can occur when installing the Krisp application on Windows.
Error code | Description |
---|---|
112 | The temporary files folder has run out of file space. This error may also occur when there is not enough disk space for the database backup. |
1602 | The user cancels the installation. |
1603 | Typically a result of a Windows System Policy preventing the Sync installer from running. |
1618 | Another installation is already in progress. Complete that installation before proceeding with this installation. ERROR_INSTALL_ALREADY_RUNNING |
2147942405 | Access is denied. 0x80070005 - ERROR_ACCESS_DENIED |
2147943550 | The specified program requires a newer version of Windows. 0x8007047E - ERROR_OLD_WIN_VERSION |
2147944022 | Error opening installation log file. Verify that the specified log file location exists and that you can write to it. 0x80070656 - ERROR_INSTALL_LOG_FAILURE |
3010 | A restart is required to complete the installation. This message is indicative of success. This does not include installs where the ForceReboot action is run. |
259 | A special return code and it has nothing to do with the MSI. It is a SCCM error code that indicates that the install time has been exceeded. |
32 | The process cannot access the file because it is being used by another process. |